Sale!

KnuKonceptz Bassik 3 Way 0 Gauge to 0 – 4 Gauge Mini ANL Fuse Block w Fuses

$10.02

859

  • Input Gauge: 1/0 AWG
  • Condition: New
  • All returns accepted: Returns Accepted
  • Input/Output: 1 In-3 Out
  • Item must be returned within: 30 Days
  • Restocking Fee: 20%
  • Return shipping will be paid by: Buyer
  • Output Gauge: 1/0 AWG
  • Refund will be given as: Money Back
  • MPN: BK-2030
  • Brand: KnuKonceptz

Description

Amp Kits
Fuse Blocks
Fuses
HDMI Cables
Power Wire
RCA Cables
Sound Dampeners
Speaker Wire
Terminals
Amp Kits
Fuse Blocks
Power Wire
RCA Cables
Speaker Wire
Terminals
Description
KnuKonceptz 0 Gauge 3 Way Fuse Block
The BK-2030 inputs accepts two 0 – 4 gauge and output two 0 – 4 gauge and one 4 – 8 gauge power wire without the use of adapters. Oversized allen screws can secure either gauge without any modification or additional parts to complicate the design.
Bassik – simple, clean, easy. This is the foundation of what KnuKonceptz calls Bassik. Easy to install, simple to connect and cost effective. This block is shown in satin nickel finish with polished nickel plated allen screws and smoke black base. The BK-2030 includes three fuses to configure this block for power applications.
PLEASE NOTE FUSE SIZE IN eBay ORDER NOTES
Fuses Sizes – 40 / 60 / 80 / 100 / 120 /150 / 200 / 240
We will ship 200A / 40A / 80A outputs if no fuses are noted, comes as 2- 100A 3- 40A fuses!
Specifications
Product FAQ
Additional Images
Related Products
Specifications
KnuKonceptz BK-2030 3 Way Fuse Block
Dimensions
3.65″(L) x 3.10″(W) x 1.25″(H)
Input Gauge
Two 0, 2, or 4 Gauge
Output Gauge
Two 0, 2, or 4 Gauge and One 4, 6, or 8 Gauge
Fuse Type
Mini-ANL
Finish
Nickel Silver
Back to top
Additional Information
Flexibility – Dual Cable Inputs
The BK-2030 Fuse Block has dual cable inputs, only one is required to power all three outputs. With the second cable port you can:
Daisy chain additional blocks for additional outputs in larger systems
Connect to a rear mounted battery, linking it to the rest of your system
Add a capacitor into the system
Using both inputs from a battery source will reduce voltage loss
IF Installing a combined fuse rating over 350A (total sum of fuses installed), connecting both inputs to a battery source is advised.
High Current Capacity – Fuses in Parallel
Using multiple smaller fuses in parallel reduces voltage loss across the connection
This is from the increased surface area of a multiple fuses
versus a single fuse
Less voltage loss means more power to your system
Achieve higher amperage capacity in a compact space. Multiple smaller fuses can achieve higher loads than a single fuse due to thermal capacity
When ordering, you will receive two fuses per 0 gauge circuit and a single fuse for the 4 gauge output.
The 0 Gauge Fuse will total the fuse rating you selected. Ex: ordering 240A fuse, you will receive 120Ax2 per 0 Gauge output (240A total)
No Adapters Needed – Oversized Hardware
Internal gauge adapters add unnecessary contact points
Extra contact points can increase resistance, lowering your voltage.
By using larger diameter set screws, our block can hold a large or small gauge wire without the need for an adapter
Back to top
Product FAQ
Q:
How do I determine what size fuses I need for this fuse block?
A:
Each output of a fuse distribution block normally is connected to a single amplifier. Each amplifier will have either a fuse on board or the manufacture will state within the manual’s installation guide or spec sheet what the max fuse rating or current draw of the amplifier is. If your amp has three 30A fuses on boards, you want a 100A fuse for that particular output of this block (90A is not an option we offer). If the second amp has a single 40A fuse, then a 40A fuse goes into that output of the block and thus a 100A and 40A would be required.
Q:
The 0 Gauge output on the BK-2030 uses two fuses, why?
A:
To achieve higher load capacity, the fused 0 gauge output each use two Mini-ANL fuses. When ordering your fuse block, all fused 0 gauge outputs will include two fuses, half the size of the load requested. For example, if you order the BK-2030 with 240A fuses on the 0 gauge output, you will receive 120Ax2 per output.
Q:
This block has two inputs, do I need to use both?
A:
The BK-2030 has two input ports, only one input is required to power both fused outputs. The second port is optional and can be used to connect additional rear mounted batteries, a capacitor, or to daisy chain additional blocks together. Having the second port makes this fuse block more flexible to the installer than a single port block.
IF Installing a combined fuse rating over 350A (total sum of fuses installed), connecting both inputs to a battery source is advised.
Q:
Can I use this block as a ground block?
A:
Yes, KnuKonceptz offers ground links to turn this block into a 5 Way Ground Block. These Mini-ANL buss bars replace the fuse and allow the BK-2030 to be used from a common grounding point.
Back to top
Related Products
KnuKonceptz Amp Kits
Pair this block with one of our amp kits for a two amp installation
KnuKonceptz Battery Cable
Connect your knu block with one of our three series of cables
KnuKonceptz Tinned Copper Ring Terminals
Tinned copper rings are a perfect way to terminate your cable. Our heat shrink is glue lined to create a water tight seal.
KnuKonceptz Mini-ANL fuses
Add some spare fuses to your order, just in case!
Back to top
About
Policy
Shipping
FAQ